The exact space needed to construct a data center will depend on several important factors. However, note that to construct a small data center, you will require within 1,000–5,000 square feet, whereas a larger facility that features high-density racks in addition to extensive cooling requirements will need around 10,000–50,000 square feet or more.
According to industry estimates, each rack will need within 25–30 square feet, including aisle space; however, keep in mind that the necessary supporting infrastructure such as cooling and power will double the required area.
To ensure that the area will be adequate to accommodate growth and additional equipment, you should plan for additional space beyond immediate needs, potentially increasing the size by 25–50% or more.
Factors That Determine How Much Space in Square Foot Needed to Construct a Data Center
-
IT Equipment Density and Rack Requirements
When designing a data center, you must take into account the volume of IT equipment, like the servers, networking devices, and storage units.
Note that data center servers and equipment are most often organized in racks, and the space you need will often depend on the number of racks as well as the density of each rack.
However, keep in mind that a single rack will need around 25–30 square feet of space especially when you take into account the physical rack footprint as well as the ideal aisle space necessary for airflow and technician access.
Additionally, if the data center will feature high-density racks, which will come with more servers and can have power and cooling needs exceeding 10 kW per rack, then you might want to consider the space needed for the additional cooling systems and aisle spacing.
-
Power and Cooling Infrastructure
In a data center, you can’t afford to underestimate the importance of cooling systems because of the high-powered servers that generate substantial heat, particularly in high-density environments.
Keep in mind that data centers utilize a wide array of cooling methods, like raised floors for airflow, cooling racks, or in-row cooling units.
However, it is pertinent to point out that each cooling approach comes with its space requirements. For instance, traditional cooling systems would require raised floors, and this will add to the ceiling height and floor space.
Additionally, liquid-cooled or modular cooling setups will limit the amount of space required but will necessitate planning to integrate with other infrastructure.
Do not also forget that data centers require adequate space to accommodate power distribution units (PDUs), backup generators, and uninterruptible power supply (UPS) systems, which work to guarantee continuous operation in case of power disruption.
-
Operational Areas and Accessibility
Aside from IT equipment and cooling, it is important to point out that data centers always require extra space for operational purposes. This will encompass areas for control rooms, workstations, security checkpoints, storage, as well as repair stations.
Keep in mind that these spaces are very necessary for day-to-day operations, especially when it comes to ensuring that personnel can adequately manage and maintain the equipment efficiently.
You would need to design your data center to have adequate space: clear aisles between racks ensure that technicians have adequate space to get to equipment without difficulty.
According to industry standards, data centers will require a minimum of 4 feet of clearance in front and back of racks. You also want to note that a poorly designed layout will in many ways impede accessibility and heighten the risk of downtime or accidents.
-
Redundancy and Disaster Recovery Needs
Note that redundant power and cooling infrastructure will indeed require extra space. For example, if you are constructing a Tier III or Tier IV data center, known to guarantee more comprehensive levels of uptime, you will need to put in place additional infrastructure that will include duplicate power sources, extra cooling units, and backup equipment.
Aside from that, you will also have to put in place disaster recovery infrastructure, such as fire suppression systems, flood protection measures, and physical security mechanisms. Note that every one of the above will contribute to heightening your square footage requirements.
In addition, you might also want to consider aisle spacing, access control zones, and structural reinforcements to be sure the data center is adequately protected against physical threats.
-
Future Expansion and Scalability
You must take into account future growth when determining the amount of space needed for a data center. When you consider the rapid evolution of technology, you will understand why modern companies need to scale up their infrastructure as data demands grow.
As such, making plans for additional square footage during initial construction gives adequate room for restricted scaling, limiting the need for disruptive renovations in the future.
Aside from that, note that expansion planning might entail putting in place flexible floor space to fit in more racks, extra cooling capacity for higher-density racks, or adaptable power distribution systems.
You can also choose to follow the trend of modular data centers, where each module operates and serves the necessary data needs independently but can be added as required. This has proven to be the solution that gives room for scaling without necessitating excessive space initially.
Nevertheless, a modular design could still need additional space to guarantee new modules can fit without compromising operational efficiency.